Restore the wall that is keeping water out of the floor system — matching what exists where we can, replacing an elevation cleanly where we cannot.

How it is priced
Per elevation or per square, itemized quote
Timeline
Set in your written estimate, after the walk-through
Who performs it
NRBS crews, self-performed

The wall is part of the floor system's protection

Siding on a manufactured home is doing what siding does anywhere: shedding water away from the structure. The consequence of failure, though, is specific to this construction.

Water that gets behind the siding runs down inside the wall cavity and arrives at the bottom plate and the floor system. There is often no interior sign at all — no stain, no smell, no visible damage — until the floor along that exterior wall goes soft, sometimes years later.

This is why we treat an exterior repair as urgent earlier than it looks. A cracked panel and a failed sealant joint at a window head are cheap. The subfloor replacement they cause is not.

Substrates, and what each needs

Vinyl lap. The most common on homes from the last twenty-five years. Profiles and colours from roughly the last fifteen are usually still available, which makes single-panel repair realistic. Older colours have often faded far enough that even a correct match reads as new.

Metal panel. Common on older homes. Durable but easily dented, and profiles are frequently discontinued. Damage is often better addressed by replacing an elevation than by hunting a match.

Hardboard composite. Used widely into the 1990s and the one to know about. It absorbs water at cut edges and at fastener penetrations, then swells and delaminates. Once that has started it cannot be refinished — paint over swollen hardboard fails within a season and takes the labour with it. It gets replaced.

Matching, honestly

We will match where matching produces a result you cannot pick out from the street, and we will say so plainly where it will not.

The failure mode to avoid is a near-match: a panel in almost the right profile, or the right profile in a colour that has drifted, patched into the middle of an elevation. It reads as a repair from a hundred feet away, and on a community perimeter that is worse than the damage was — because damage reads as an accident and a bad patch reads as the standard.

Where a match is not available, replacing the full elevation gives a clean result and is often barely more expensive than a careful patch once the labour of hunting material is counted.

The details water actually uses

Window and door headsFlashing and sealant at the head — the most common entry point on any elevation
PenetrationsHose bibs, dryer vents, electrical, and every past cable installation
Bottom courseAt the skirt line, where splash-back and mower damage concentrate
CornersCorner posts and trim, where two planes meet and movement is greatest
Past repairsSealant applied over a problem rather than a repair — extremely common, and it hides what is underneath
Also in exterior & envelope

What the price covers

In the scope

  • Common substrates: Vinyl lap, metal panel, and hardboard on older homes
  • Matching: Profile and colour matched where available; whole-elevation replacement where not
  • Water detailing: Window and door heads, penetrations, and the bottom course at the skirt line
  • Hardboard note: Swollen or delaminated hardboard is replaced, never refinished

Not in the scope

  • Anything not written in the scope. Extra work found on site is raised as a written change order before it is done.

How the job runs

  1. Walk-through

    We walk the job with you in person and look at what is actually there.

  2. Written scope

    A written scope and price before any work starts, priced as shown above.

  3. The work

    Our own crews do it, to the written scope. Anything extra is a written change order first.

  4. Final walk-through

    We walk it again with you and close out anything on the punch list.

Step one is a walk-through.

Get a quote

Common questions

Sometimes. Vinyl profiles and colours from the last fifteen years are usually available. Older metal panels and discontinued profiles frequently are not, and in that case the honest answer is to replace a full elevation rather than patch with a near-match that draws the eye to the repair from the street.

Composite hardboard was used widely on manufactured homes into the 1990s. It absorbs water at cut edges and fastener penetrations, then swells and delaminates. Once that has started, it cannot be refinished — paint over swollen hardboard fails within a season. It gets replaced.

Water that gets behind the siding runs down inside the wall cavity and reaches the floor system at the bottom plate. It shows up as a soft floor along an exterior wall, often years later, with no visible clue on the inside. That path is why a siding repair is worth doing before it is urgent.

Whichever is honest. A single damaged panel in an available profile is a panel replacement. Several panels across an elevation, or a discontinued profile, is a whole-elevation job — patching it produces a wall that reads as repaired from a hundred feet away.

W-9, written safety programme and certificates of insurance (GL and workers’ comp): being prepared. What is published so far is on vendor credentials.