Restore a metal roof that is still structurally sound, and replace the one that is not — with a straight answer about which you have.

How it is priced
Per square foot for coating; per square for panel replacement
Timeline
Set in your written estimate, after the walk-through
Who performs it
NRBS crews, self-performed

The assessment comes before the recommendation

A commercial metal roof is either a restoration candidate or a replacement, and which one it is should be established by walking it rather than by what the contractor sells.

PanelsSurface rust is treatable. Perforation and structural corrosion are not.
FastenersBacked out across the field means the panel-to-purlin connection is failing. A coating does nothing for that.
SeamsSplit or opened seams need mechanical repair before any coating, not instead of it.
Deck and structureInterior staining and a soft deck mean water has already been getting in for a while.
DrainagePonding areas determine the chemistry — and sometimes determine that coating is the wrong answer.

Where the answers are good, restoration is genuinely excellent value: a fraction of replacement cost, applied quickly, minimal disruption to the building's occupants, and it resets the maintenance clock.

Where they are not, we will say the roof needs replacement. That is a bigger number and a less comfortable conversation, and it is still the right recommendation — a coating over a failing metal roof postpones the decision by one budget cycle and makes it more expensive when it arrives.

Chemistry, and what each is for

A single service-life number with no chemistry attached is a marketing figure, not a specification.

Service life

Acrylic
5–10 years
Elastomeric
7–12 years
Silicone
10–15 years

Relative cost

Acrylic
Lowest
Elastomeric
Middle
Silicone
Highest

Standing water

Acrylic
Does not tolerate it — needs positive drainage
Elastomeric
Tolerates limited ponding
Silicone
Handles ponding; this is why it exists

Best fit

Acrylic
Dry climate, well-drained pitched metal, shorter hold period
Elastomeric
General purpose on a sound pitched metal roof
Silicone
Low slope, imperfect drainage, or a long hold

Preparation and applied thickness

Restoration failures are almost never coating failures. They are two things.

Preparation. A coating over a surface that was not washed, over rust that was not treated, or over seams and fasteners that were never detailed, will fail at exactly those points — regardless of which product went on top.

Applied thickness. Coatings are specified in dry mils, and a coat applied at half the specified thickness looks identical on the day of completion and lasts roughly a third as long. It is the most commonly short-changed item in this scope precisely because nobody can see it. We record applied thickness as part of the close-out documentation rather than asking you to take it on trust.

For the manufactured-home equivalent of this scope, see metal roof recoat.

Also in commercial roofing

Specification

What we install, and to what standard.

Full specification
Restoration
Wash, rust treatment, seam and fastener detailing, then a coating system
Coating chemistries
Acrylic 5–10 yr, elastomeric 7–12 yr, silicone 10–15 yr
Fastener assessment
Backed-out fasteners across the field indicate a connection problem coating cannot fix
Replacement trigger
Perforation, structural corrosion, or a deck that has already failed

Not in the scope

  • Anything not written in the scope. Extra work found on site is raised as a written change order before it is done.

How the job runs

  1. Walk-through

    We walk the units or the roof, or work from the walk sheet you already have.

  2. Written scope

    A written scope and price before any work starts, priced as shown above.

  3. The work

    Our own crews do it, to the written scope. Anything extra is a written change order first.

  4. Final walk-through

    We walk it again with you and close out anything on the punch list.

Step one is your scope, as it already exists.

Request a bid

Pricing a whole community? Request a park-wide quote.

Common questions

When the panels are structurally sound, the fasteners are holding, the seams are intact, and there is surface rust rather than perforation. Under those conditions a restoration coating is excellent value — a fraction of replacement cost, installed quickly, and it resets the maintenance clock.

When there is rust through rather than surface rust, when fasteners have backed out across the field, when seams have opened, or when the deck below has already been wetted. Coating any of those buys a season and makes the eventual repair more expensive, because the coating has to come off first.

By chemistry — acrylic five to ten years, elastomeric seven to twelve, silicone ten to fifteen. Silicone is the choice where drainage is imperfect because it tolerates ponding; acrylic needs a dry climate and positive drainage.

Manufacturers offer warranties on restoration systems, and the terms depend on the chemistry, the applied thickness and the preparation. Applied thickness is the item most commonly short-changed and it is invisible on completion — a coat at half the specified mils looks identical on the day and lasts a third as long.

W-9, written safety programme and certificates of insurance (GL and workers’ comp): being prepared. What is published so far is on vendor credentials.